Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

General Parameters
Transformer Parameters

  • Name of primary XFO Bus: Name of the bus on the high voltage side of the static compensator transformer;
  • Primary XFO V: Line-line rated voltage on the primary side of the transformer (kV rms);
  • Secondary XFO V: Line-line rated voltage on the secondary side of the transformer (kV rms).
  • Leakage: Leakage inductance of the primary winding of the transformer (pu/100MVA);
  • Y (Lag, Lead): Specifies the connection of the transformer and the Delta windings lagging or preceding the Y winding.

Control System Parameters

  • Source of control: Where the control system is modelized (Intern = Internal, External, Simulink);
  • Firing order: (Internal, External);
  • Directory: Directory where the HyperLink model is saved;

Name of HyperLink model

  • Execution time: Estimated execution time for the HyperLink model.
  • Precision valve: Specifies if the user wants to use the precision valve model


  • No labels