Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

FIRST – [XFIRST]
Outputs the sampling time of the first data in the acquisition buffer.


CATEGORY
Miscellaneous

DESCRIPTION
Outputs the sampling time of the first data of the input stored in the acquisition buffer in seconds [s].


RESULT VARIABLES AND PARAMETERS

ResultSampling time of the first data [s]
SignalInput


SYNTAX

res = xfirst(input)


CHARACTERISTICS
Data type support
Double Floating point


EXAMPLE
In the below example, the acquisition is started exactly at the same time as the trigger condition (without time offset). Sampling time of the first data is then 0 second.

  • No labels