Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Connected I/O module is OP48H10 Fast I/O type H Module

...

Note

Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37specifications of I/O module OP48H10.

Connector P1 (top)
Slot 1 - Section A - Channels 00 to 15

image-20240703-201738.png

Note

Do not connect to external power supply

Connector P2 (bottom)
Slot 1 - Section A - Channels 16 to 31

DB37F Pin

Assignment

DB37F Pin

Assignment

DB37F Pin

Assignment

DB37F Pin

Assignment

1

+DIO00

20

GND

1

+DIO16

20

GND

2

+DIO01

21

GND

2

+DIO17

21

GND

3

+DIO02

22

GND

3

+DIO18

22

GND

4

+DIO03

23

GND

4

+DIO19

23

GND

5

+DIO04

24

GND

5

+DIO20

24

GND

6

+DIO05

25

GND

6

+DIO21

25

GND

7

+DIO06

26

GND

7

+DIO22

26

GND

8

+DIO07

27

GND

8

+DIO23

27

GND

9

+DIO08

28

GND

9

+DIO24

28

GND

10

+DIO09

29

GND

10

+DIO25

29

GND

11

+DIO10

30

GND

11

+DIO26

30

GND

12

+DIO11

31

GND

12

+DIO27

31

GND

13

+DIO12

32

GND

13

+DIO28

32

GND

14

+DIO13

33

GND

14

+DIO29

33

GND

15

+DIO14

34

GND

15

+DIO30

34

GND

16

+DIO15

35

GND

16

+DIO31

35

GND

17

Reserved

36

GND

17

Reserved

36

GND

18

Reserved

37

Reserved

18

Reserved

37

Reserved

19

GND

19

GND

Info

The digital input/output threshold/level are configurable to TTL 5 V or 3.3 V using the OPAL-RT Boards configuration interface in RT-LABor in the Block Parameters: Mezzanine Option Block in MATLAB/Simulink using S-Function blocks.

The OP48H10 32-channel digital IOs configured per 8-channel subsections to be used as digital inputs or digital outputs. The following table is a list of parameters to configure as input or output.

...

DIGITAL INPUT BLOCK PARAMETERS

Parameters

CH00-07

CH08-15

CH16-23

CH24-31

Controller Name

'OP810 OpCtrl'

Data Out Port Number

3

4

5

6

Number of channels

8

Digital Input Type

  • Static Digital In

  • Event Detector

  • Pulse-Width Modulated Input

Info

In addition to the parameters listed above, other parameters may need to be configured. More information on the Din and Dout parameters can be found here: OP48H10 Fast I/O type H Module.