Page Content

...

For a simple functional test of your system, you can execute one of the model examples provided as demos.
For example, you can load and execute the “rtdemo1” demo model, which is a PID controller. This model does not use the I/Os of your system.
If this model is running as expected, you know that your system basic configuration is correct.

The procedure is explained in this page of the RT-LAB user documentation: https://opal-rt.atlassian.net/wiki/x/MoiPC

...

We provide you the integration test model used to test your system in the factory.

Info

Please, refer to this page in the RT-LAB user documentation for a detail: https://opal-rt.atlassian.net/wiki/x/_QiPC

Note

The model includes the bitstream you should always use.

Download the integration test model file below on your PC.

...

Expand
title🟢 EXAMPLE: Click to expand and view the Analog In example

Analog in

Path to this view: IO_test/SC_Console/OP4512/GR2A AIN (CH00-15)
Note: Open the scope window for of each input block by double-clicking on a block or via the right-click menu (showed below).

image-20241031-161259.pngimage-20241031-161424.png

See Also

Note

Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37/DB9 specifications of I/O modules OP5330, OP5342 and, OP5369. See section HIL2GO-100 - OP4512 I/O System for all DB37 and DB9 pin assignment.

Use the Integration Test Model (Loopback Test)

...

  • Use the current workspace or use an existing workspace or create a new workspace in RT-LAB.

  • Import the integration test model in RT-LAB

    • Click File > Import

    • Select General > Existing Projects into Workspace

    • Choose Select archive file, then click the Browse button

    • Select the downloaded zip file and click Open, then click Finish

  • Build the integration test model

    • In the “HIL2GO_100_integration_test” tree, click Models.

    • Right click on IO_test and select Simulation > Build configurations…

      image-20241023-215039.png
    • Select your target (simulator) in the drop-down list “Development Node: on OPAL-RT (x64-based)

    • Click OK.

      image-20241023-215746.png
    • The model start building up. When done, the build log can be viewed under the Compilation tab in the bottom right panel.

    • Load the model.

    • Execute the model.

    • Use the MATLAB Simulink console to view signals and check if all the inputted signals corresponds to the outputted signals.