During system definition deployment, the VeriStand engine collects and records information in a log file saved on the real time target.  Real Time Target Logs can provide valuable clues about the state of the Power Electronics Add-On in the event of a deployment or run-time error.  The procedure below describes how to obtain the log files and analyze them.

...

  1. Open the NI Measurement and Automation Explorer (NI MAX).
  2. In the configuration tree, expand Remote Systems and locate your Real Time PXI target.
  3. Right-click the target and click File Transfer to navigate the target files over FTP.

    Info

    The files on the real time target can also be accessed using a third party SSH tool such as PuTTY, MobaXTerm, etc.






  4. Navigate to /c/ni-rt/NIVeriStand/Logs/ and identify the desired log file using the date in the file name: VeriStand Engine Log <Date>.txt.
  5. Open the file to view its contents or copy them to a local text file.


Status messages originating from the Power Electronics Add-On can be identified by the text PEA: at the start of the line.  The sample log below was generated after the successful deployment of the PMSM VDQ Local Control example model:


...