Page Content
Table of Contents | ||
---|---|---|
|
Version 2.8.0
Features
Matlab 2022a is supported.
Vivado 2019.1 and later versions are supported.
Deprecation and Removals
Dropped support of the following Matlab versions: 2015b, 2016a/b, and 2017a/b.
Dropped support of Vivado 2018 and earlier versions.
Version 2.7.0
Features
Matlab 2021a/b are supported.
Bug fixes
Fixed the bug that in MMC FPGA model, the total voltage drop on IGBT Ron is wrong when the value is larger than 512 V. If the customer uses pregenerated bitstream from previous version, they need to replace the bitstream with the one comes in this version. If the customer uses bitstream generated from their own RTXSG model, they will need to re-generate new bitstream in this version to fix the bug.
Deprecation and Removals
Due to above bug, bitstreams of previous version are removed and replaced with new bitstreams.
Version 2.6.0
Features
VSC switch thermal model block is added in library.
Bug fixes
Fixed the bug that Compilation failed using gcc on
OPALRTLinuxOPAL-RTLinux due to two incompatible S-functions.
Version 2.5.0
Features
A new SST demo added.
The 6-IGBT NPC SM type is supported.
Block help is linked to wiki webpages.
Bug fixes
Fixed the bug that in VSC model, the external capacitors with upper/lower capacitors give wrong results.
Version 2.4.0
Features
Bug fixes
...
Bug fixes
Version 2.2.0
Features
Added new demo of VSC switching function -- TSB AC/AC Converter in CPU.
Added new demo of MMC HVDC in CPU, it combines MMC CPU detailed model and average model in one demo.
Added MMC RT-XSG model for the demo bitstream.
Version 2.1.0
Features
Support for new Matlab versions. Add support of Matlab 2019a and Matlab 2019b.
Version 2.0.0
Features
Support for new MATLAB versions. The official list is now 2015b, 2016a, 2016b, 2017a, 2017b, 2018a and 2018b.
Support Sub-module states transmission in new protocol in MMC FPGA models. Please note in this version no protocol communication is supported in OP4510.
Bug fixes
Version of MMC showing in MATLAB command window when the command 'ver' is given.
Reworked the libraries displayed in the Simulink Library Browser.
Updated MMC unitary test procedure.
Added documentation for RT-XSG blocks which are inside the MMC library.
Fixed the bug that MMC demos cannot be compiled on windows target.
Added all MMC examples in RTLAB New Project wizard (supported with RTLAB 2019.3 and above).
Deprecation and Removals
Dropped support of the following Matlab versions: 2011b, 2012b, 2013b and 2014b.
Version 1.0.0
Features
MMC6 Hybrid MMC models in FPGA are available. The MMC can have up to three types of SM (e.g. Half-bridge sub-module (HBSM), Full bridge sub-module (FBSM), Clamped double sub-module (CDSM), or T-Type sub-module) in one valve.
MMC6 Hybrid MMC RT-XSG model and bitstream compilation are only available in Xilinx Vivado.
This MMC version supports FPGA types OP7020, OP5607 and OP4510.
Software Artemis 7.2.1 and upper, RTLAB 11.2.1 and upper and RT-EVENT are needed to run MMC demos.
This MMC version supports Matlab 2011b, 2012b, 2014b, 2015b and 2016b.