It can contain two sets of parameters:

  1. Parameters for the Spatial Harmonics model (3D tables describing Phase Inductance, Phase Total Flux, and Torque)

  2. Parameters for the Variable DQ model (2D tables describing Direct Inductance, Quadrature Inductance, and Magnet Flux)

It is important to generate Spatial Harmonic Model data for use with the PMSM SH Machine.

Spatial Harmonics Data Generation

The tables generated for the Spatial Harmonics model plot Phase Inductance, Phase Total Flux, and Torque values along the three following axes:

Axis

Description

Theta

Mechanical angle of the rotor.

Beta

Polar angle of the [Id, Iq] vector in the DQ reference frame, where Id is Direct Axis Current and Iq is Quadrature Axis Current. JMAG uses the power invariant DQ transform convention where the D axis is aligned with Phase A at Theta = 0.

Iamp

Amplitude of the [Id, Iq] vector in the DQ reference frame, where Id is Direct Axis Current and Iq is Quadrature Axis Current

The tables are formatted as follows:

Parameter

Number of Tables

Theta Axis Minimum Length

Beta Axis Minimum Length

lamp Axis Minimum Length

Phase Inductance

9

65 samples [0 ... 180/Number of Pole Pairs]

33 samples or more [0 ...  360]

32 samples or more [0 ...  3*maximum peak phase current]

Phase Total Flux

3

129 samples [0 ... 360/Number of Pole Pairs]

33 samples or more [0 ...  360]

32 samples or more [0 ...  3*maximum peak phase current]

Torque

1

65 samples [0 ... 180/Number of Pole Pairs]

33 samples or more [0 ...  360]

32 samples or more [0 ...  3*maximum peak phase current]

The information in brackets represents the allowable range of values for the axis.

...

Before they are transferred to the machine model on the FPGA, the data tables are reshaped using a trilinear interpolation method.   The resulting tables are made up of equally spaced samples and are resized according to the parameters described below. The size of each table is dependent on the version of the PMSM SH model, as well as the number of enabled machines in the simulation. Because the data in the resized tables is equally spaced, the resolution across each axis can be calculated by dividing the maximum possible value along the axis by the number of samples used.

Info

Please refer to the description page for your Hardware Configuration to confirm the version of the PMSM SH model. Additional information can also be found under Permanent Magnet Synchronous Machine Models Comparison.

Single Machine Mode

The memory space of the PMSM SH model core is shared between the two machine models. When a single machine is enabled, the full size of the table is available to model the machine. The default number of samples for each axis is shown below.

PMSM SH v2

Theta Axis (Electrical angle)

Beta Axis

Iamp Axis

Phase Inductance

65 samples per half-electrical turn (Resolution 2.77 deg)

33 

33 (Resolution 10.9 deg)

32 (Resolution IampMax / 32 Amps)

Phase Total Flux

65 samples per full-electrical turn (Resolution 5.54 deg)

33 

33 (Resolution 10.9 deg)

32 (Resolution IampMax / 32 Amps)

Torque

65 samples per slot (1/6 of electrical turn) (Resolution 0.92 deg)

33 

33 (Resolution 10.9 deg)

32 (Resolution IampMax / 32 Amps)

PMSM SH v1

Theta Axis (Electrical angle)

Beta Axis

Iamp Axis

Phase Inductance

33 samples per half-electrical turn (Resolution 5.45 deg)

33 

33 (Resolution 10.9 deg)

16 (Resolution = IampMax / 16 Amps)

Phase Total Flux

65 samples per full-electrical turn (Resolution 5.54 deg)

33 

33 (Resolution 10.9 deg)

16 (Resolution = IampMax / 16 Amps)

Torque

33 samples per half-electrical turn (Resolution 5.45 deg)

33 

33 (Resolution 10.9 deg)

16 (Resolution = IampMax / 16 Amps)

Dual Machine Mode

When both PMSM SH machines are enabled, the total allocated FPGA memory is divided between the two machine models.  The default number of samples for each axis is shown below.

PMSM SH v2

Theta Axis (Electrical angle)

Beta Axis

Iamp Axis

Phase Inductance

33 samples per half-electrical turn (Resolution 5.45 deg)

33 

33 (Resolution 10.9 deg)

32 (Resolution = IampMax / 32 Amps)

Phase Total Flux

33 samples per full-electrical turn (Resolution 10.9 deg)

33 

33 (Resolution 10.9 deg)

32 (Resolution = IampMax / 32 Amps)

Torque

33 samples per slot (1/6 of electrical turn) (Resolution 1.98 deg)

33 

33 (Resolution 10.9 deg)

32 (Resolution = IampMax / 32 Amps)

PMSM SH v1

Theta Axis (Electrical angle)

Beta Axis

Iamp Axis

Phase Inductance

33 samples per half-electrical turn (Resolution 5.45 deg)

17 

17 (Resolution 21.17 deg)

16 (Resolution = IampMax / 16 Amps)

Phase Total Flux

65 samples per full-electrical turn (Resolution 5.54 deg)

17 

17 (Resolution 21.17 deg)

16 (Resolution = IampMax / 16 Amps)

Torque

33 samples per half-electrical turn (Resolution 5.45 deg)

17 

17 (Resolution 21.17 deg)

16 (Resolution = IampMax / 16 Amps)

Data Interpolation Performed During Simulation

...