As presented in table 1, a PELab-6PH can be configured for different power rates. For more details, please consult the user guide published and updated by Taraz Technologies.
Table 1. PELab-6PH Power Configurations
Configuration | Maximum DC-Link Voltagelink voltage | Nominal Currentcurrent | DC-Link Capacitancelink capacitance |
---|---|---|---|
1 | 800 V | 8 A | 470 uF |
2 | 400 V | 16 A | 1500 uF |
3 | 200 V | 16 A | 2700 uF |
4 | 800 V | 30 A | 400 uF |
5 | 80 0V | 50 A | 400 uF |
In the rest of this user guide, the main focus is on the first configuration as it is available in the laboratory for model development and testing.
The following table also provides more details in terms of hardware, limitations, protection, and dimensions, for the first configuration of PELab-6PH.
...