Toolbox | Version Number |
---|---|
7.9.0 | |
2024.2 | |
2.17 | |
2.12 | |
4.7.7 | |
3.5.0 |
Added
Added a message to warn the user that the RT-LAB 2024.1 versions will be the last to support TestDrive and the creation of new LabVIEW panels.
Added a UI option in RT-LAB to migrate oprec files from format 1.02 to 1.03.
The “Panels“ section in the ProjectExplorer will be visible only for existing projects that already used VI panels.
...
Improved the execution logs by adding message when using the Restore Snapshot feature.
The FPGA Scope workflow has been greatly improved by allowing signals to be selected directly in ScopeView.
Improved the management of target statuses to avoid slow downs when several targets are offline.
In Orchestra, the user is not required anymore to use quotes when specifying the DDF file or domain.
Improved target management stability
Replaced in some example model, LABVIEW and TestDrive pannels used to interact with the real-time simulation by new Dashboard panels. The Simulink console has also been removed from those models. The following examples are affected: rtdemo1, rtdemo2, rtdemo3, Abaco ARINC429, TCP-UDP_loopback and DataLogger.
ProbeControl user interface is now in 64 bits.
...
Removed support for the 32 bits RedHat target operating system. The RT-LAB 2024.1.X releases must now be used to keep using the RedHat.
Removed deprecated python hooks target_postload.py, target_postpause.py and target_preexecute.py
Test Automation
Data Logger Python API
The
SignalGroupInfo
object has been updated to simplify its usageget_id()
method is now deprecated and will be removed from the next release.get_filename()
method is now deprecated and will be removed from the next release.get_port()
method is now deprecated and will be removed from the next release.the representation (
__repr__)
of aSignalGroupInfo
object has been modified to hide internal and irrelevant data. No code should rely on this representation.
The connection to a
SignalGroup
has been updated to simplify its usageconnection with ip and port number is now deprecated and will be removed from the next release.
it is now encouraged to directly provide a
SignalGroupInfo
object to connect to aSignalGroup
. This will be the only way to connect to aSignalGroup
in the next release.
I/O Interfaces
Added OPAL-RT Board and S-Function support for OP4810-IO and OP4815-IO expansion chassis based on AMD Versal FPGA technology.
Added support for the OP5367-6 mezzanine.
...
Fixed the FPGA Scope crash when FPGAScopeTool is killed and restarted manually or the simulation is reset and loaded
MMC
Improved
Improved the MTDC HVDC example model by allowing the user to select FPGA or CPU implementation in the same model
Improved the generated block to provide frequency as input and not only as parameter
EXata CPS - Communication Network Toolbox
...
View file | ||
---|---|---|
|
...