Command switches | Associated function | |||||
| Default status, no action. | |||||
PSS is activated until the system is stabilized. | ||||||
| The generator has no rotor damper windings. | |||||
The generator has rotor damper windings to damp torque oscillations | ||||||
| Default status, no action. | |||||
Fault is triggered on bus 1. | ||||||
| Default status, no action. | |||||
Fault is triggered on bus 3. | ||||||
| Default status, no action. | |||||
Switches are closed: the line between buses 1 and 3, and between buses 3 and 2 are reconnected. | ||||||
| The trigger function is inactive. Signals are not synchronized with respect to a reference signal. | |||||
Signals are synchronized with the oscillations' frequency of the system. | ||||||
| The trigger function is inactive. | |||||
The oscilloscopes are waiting for a fault initiation to display the signal waveforms for 6 seconds. |
Table 3: Control switch descriptions
Anchor | ||||
---|---|---|---|---|
|
Control Indicators | Description | |
D1 | Switch closed (line connected) | |
| Switch open (line disconnected) | |
D2 | Switch closed (line connected) | |
| Switch open (line disconnected) | |
Damping | The generator is equipped with rotor damper windings | |
The generator is not equipped with rotor damper windings. | ||
Oscillating | The system is oscillating. | |
The system is not oscillating. | ||
Stability | The system is stable. | |
The system is not stable. | ||
PSS | The PSS is enabled. | |
The PSS is no longer enabled. | ||
Recording | Data is being saved. | |
No data is being saved. |
...
Tab | Oscilloscopes | Waveforms displayed on the oscilloscopes |
Display1 | Oscilloscope 1 | “Generator mechanical angle (degree)”. Mechanical angle of the generator delta in degrees. |
Oscilloscope 2 | “BUS 4 magnitude voltage (pu)”. Voltage magnitude in pu of phase A on bus 4. | |
y-axis scale | Setting the y-axis scale on the oscilloscope displaying the rotor mechanical angle. | |
y-axis offset | Setting y-axis offset on the oscilloscope displaying the rotor mechanical angle. | |
Display 2 | Oscilloscope 1 | “Generator mechanical angle (degree)”. Generator mechanical angle delta in degrees for 6 seconds, when a fault occurs and trigger “Trig-Acq.Gr. 2” is active. |
Oscilloscope 2 | “BUS 4 magnitude voltage (pu)”. Voltage magnitude in pu of phase A on bus 4 over a period of 6 seconds when a fault occurs and trigger “Trig-Acq.Gr. 2” is active. | |
y-axis scale | Setting the y-axis scale on the oscilloscope displaying the rotor mechanical angle | |
y-axis offset | Setting the y-axis offset on the oscilloscope displaying the rotor mechanical angle. | |
delta_file | File number for delta angle data saved during fault. | |
voltage_file | File number for bus 4 voltage data saved during fault. |
...