Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This block implements a single-phase ideal two-winding transformer (1 primary, 1 secondary).

...

Parameters


Resistance (Rm)The resistance and inductance simulating the core active and reactive losses. 

Inductance (Lm)
Primary Winding
Nominal voltage (V1)The nominal voltage V, in volts RMS, of the primary winding.
Resistance (R1)The resistance, in pu or ohms, of the primary winding.
Leakage inductance (L1)The leakage inductance, in pu or henries, of the primary winding.
Initial current (I1)The initial current A, in amperes, of the primary winding.
Secondary Winding
Nominal voltage (V2)The nominal voltage V, in volts RMS, of the secondary winding.
Resistance (R2)The resistance, in pu or ohms, of the secondary winding.
Leakage inductance (L2)The leakage inductance, in pu or henries, of the secondary winding.
Initial current (I2)The initial current A, in amperes, of the secondary winding.

...