Input impedance

> 100 kOhm

Reverse voltage protection

Diode

Maximum voltage protection

+/- 50 Volts

Detection threshold

4 programmable Schmitt trigger level step 0.118V 1176V from 0.470V 47V to 29.4V threshold high and threshold low for each bank

Recommended levels threshold

The default thresholds are LOW = 1.5V, HIGH = 3.5V. To improve noise immunity, a LOW level threshold of 1/3 Vuser and a HIGH level threshold of 2/3 Vuser are recommended.

Voltage range

0 to 30 Vdc

Delay Low-to-High

10 ns (implementation-dependent)                                                         

Delay High-to-Low

15 ns (implementation-dependent)                                                        

...

Environmental

Indoor/Outdoor

Design for indoor use only

Module operating temperature

0 °C to 40 °C

Storage temperature

-40 °C to 85 °C

Operating humidity

10% to 90% non-condensing

Storage humidity

5% to 95% non-condensing

Pollution degree

2

Maximum altitude

2,000 m

Power requirement

15 W

...