Page Content
Table of Contents | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Have a question or need help?
Auibutton | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Solution
Cfm tabs page | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
OPAL-RT provides the capability to add an OPC UA server to a real-time simulation, where the user can use an OPC UA client to monitor any kind of simulation points and is also able to control the simulation by writing data. Our OPC UA driver also offers the possibility of providing the server with an external timestamp, as opposed to the server receiving its timestamp directly from the system it is running on. For example, the user can use precision GPS timestamping to the server according to the epoch time it received through GPS. |
Cfm tabs page | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
OPC UA is an independent service-oriented communication protocol platform developed by the OPC Foundation and integrates all the functionalities of the individual OPC Classic specifications into one extensible framework. The protocol is client/server-based and relies on TCP/IP over Ethernet. |
Software Platform Compatibility
Auibutton | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Auibutton | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Product Selection Guide
OPC UA and OPC DA applications require software license OP3131, which comes with 50 data points. Visit this page more information on data points.
If additional data points are required, then they may be added via product OP3050.
For applications requiring precision timestamping, a time synchronization module may be added to the simulator.
For more information on precision timing, please visit the following page.
OPC UA
OPC UA can be added to real-time simulators without the need for additional hardware.
However, since real-time simulators come with at least one available Ethernet port, if additional physical Ethernet ports are required on the real-time simulator, these can be added via a kit.
Note that for applications requiring many Ethernet ports,the OP4510 and OP4512 simulators are not recommended.
OPC DA (classic)
OPC DA applications require the use of an external gateway to convert OPC UA to OPC DA.
For applications where the OPAL-RT simulator acts as the server, product OP3134 is required.
For applications, where the OPAL-RT simulator acts as the client, product OP3133 is required.
Type | Description | Product Number | Simulator Compatibility | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
OP4510v2 | OP5033XG | OP5600v2 | OP5700 | |||||||||
Driver | Driver license for OPC UA Server protocol. Unlimited number of client applications. 50 I/O data points are included. For additional data points, add product OP3050 (see below). | OP3251 | YES | YES | YES | YES | ||||||
Additional data points | License for additional I/O data points for Ethernet-based communication protocols. 1,000, 5,000, or 30,000 (unlimited) data points may be added. License OP3251 is required. | OP3050-1000 | YES | YES | YES | YES | ||||||
Add-on module | Required for OPC-DA (classic) or OPC-UA based CLIENT applications OPC Gateway. Enables OPC-DA (classic) or OPC-UA based client applications to connect with the OPAL-RT simulator acting as a OPC UA server. Note that this item includes the Cogent DataHub® gateway. This gateway converts real-time streaming OPC UA data to DA. Using the Gateway, you can connect any OPC DA, any OPC-UA client to the real-time simulation (OPC UA server), locally or over the plant network. | OP3133 | YES | YES | YES | YES | ||||||
Add-on module | Required for OPC-DA (classic) SERVER applications OPC Gateway. Enables OPC-DA (classic) based server applications to connect with the OPAL-RT simulator. Note that this item includes the Cogent DataHub® gateway. This gateway converts real-time streaming OPC UA data to DA. Using the Gateway, you can connect any OPC DA server to the real-time simulation (OPC UA server), locally or over the plant network. | OP3134 | YES | YES | YES | YES | ||||||
Add-on module | Dual-port PCIe X1 Gigabit Ethernet Kit for OP4xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required. | OP3821 | OP4510v2 | |||||||||
OP3821-4610 | OP4610XG | |||||||||||
Add-on module | Intel I350T4V2 Quad Port Ethernet Server Adapter 10/100/1000 Mbps for OP5xxx Series of Real-Time Simulators*. | I350T4V2BLK | YES | YES | YES | |||||||
Add-on module | Time synchronization kit with 0.1 ppm oscillator*. Supports IRIG-B, 1PPS, IEEE1588. For more information, including a full list of Precision Timing modules, visit the following page: Precision Timing Synchronization. | See here. | YES | YES | YES | YES |
* Available PCIe slot required. Note that OP4510 and OP4512 simulators only have one PCIe slot.