Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Data Point DP Licensing for Communications Protocols: FAQ
Contents OPAL-RT customers with questions as to how this affects their operations are advised to contact their salesperson or reseller directly. | ||||||||||||||||||||
Q: We've started using Data Point Licensing for the administration of Communications Protocol purchasing and support. Why is this? | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A: We have done this with the benefit of the OPAL-RT user in mind: Charging Data Point Licensing to users: · Keeps us competitive in the market · Keeps our users in the loop with the most significant progress/changes on each Communications Protocol · Enables us to support more Communications Protocols and support each one more effectively · Enables us to maintain an edge in pricing by only offering users what they need · Additionally, it helps us to better serve users by providing our communications protocols/drivers at a fair and competitive price that keeps all user types in mind, since it: o scales with performance needs o decreases when buying multiple protocols o Is limited by a maximum value o Is standardized for Ethernet-based communications protocols o Is independent of the number of cores and target performance | ||||||||||||||||||||
Q: What is a “Data Point”? | ||||||||||||||||||||
A: A data point corresponds to any data value exchanged with the simulator. It can be a Boolean, an integer, a double, a status, a string, analog, digital, coil, register, etc. It can be thought of as a variable that can be reported on. Examples · One IEC61850 Sampled Value stream corresponds to 16 data points: 4 voltages, 4 currents, and 8 statuses. · One C37.118 stream corresponds to 6 data points: 3 magnitudes, and 3 angles. We strongly recommend purchasing a pack of 1,000 DPs by default. This will cover 95% of use cases. It allows, for example, to do at the same time 30 SV and 80 PMU streams in a single simulation. | ||||||||||||||||||||
Q: Which communications protocols are affected? (And what are their part numbers?) | ||||||||||||||||||||
| ||||||||||||||||||||
Q: How are they packaged by default? | ||||||||||||||||||||
A: Default packaging is as follows: · Buy your driver: contact your salesperson/reseller for details. · Buy data points: contact your salesperson/reseller for details. · Data points can be used for any of our Ethernet-based drivers · Data points are available for all communication protocols activated and can be switched between drivers based on simulation needs | ||||||||||||||||||||
Q: How can I make modifications to the default packaging if required? What if I require a very distinct combination? | ||||||||||||||||||||
A: See Counting Up DPs, below. | ||||||||||||||||||||
Q: Can you break it down for me in a few lines? | ||||||||||||||||||||
A: To count up the number of data points you may potentially require, please see these examples: i) A typical relay that uses IEC61850-9-2 SV in a simple application · Exchanges normally between 1 to 2 SV streams · One SV stream = 16 DPs ii) A typical relay that uses IEC61850-8-1 GOOSE in a simple application · Exchanges normally between 1 to 2 GOOSE streams · One GOOSE stream = 8 DPs · More complex applications may imply dozens of DPs per GOOSE stream iii) A normal PMU that uses C37.118 · Exchanges normally between 1 to 2 streams · One C37.118 stream = 6 DP NOTE: For DNP3, IEC 60870, MODBUS and OPCUA, you will need to know the number of values you want to exchange. | ||||||||||||||||||||
Q: Okay, so how do I count it up for my entire system? | ||||||||||||||||||||
A: Counting the number of DPs Example 1 · Interface 80 PMUs with one stream. 80 x 6= 480 DPs Example 2 · Monitor 1,000 voltages and 500 currents with their status on a SCADA system using OPC-UA. (1,000 + 500) * 2 = 3,000 DPs Example 3 · Interface 4 relays using SV. Each relay needs 2 streams. 2*4*16 = 64 DPs | ||||||||||||||||||||
Customers using versions older than RT-LAB 11.2 and HYPERSIM 6.1 | ||||||||||||||||||||
· DataPoints are effective in all new releases of RT-LAB and HYPERSIM beginning November 2019. They will be first deployed in HYPERSIM 6.1 and RT-LAB 11.2. · Customers that upgrade their simulators from an older version of RT-LAB and HYPERSIM must update their simulator's license file to use the DataPoint system and will be licensed 1,000 DPs. · Note that driver licenses are still per target. This means that if you have many systems, you will have to repeat these steps for each simulator. |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter