The positive sequence shunt is used in the positive sequence network.

Positive Sequence Shunt Parameters

Symbol

Description

Unit

ID

Source name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Bus

Name of the bus its connected to

a unique name

P (MW)

Active power

MW

Q (MVAr)

Reactive power

MVAr

Available I/O pins

No

Pin Description

Pin Type

Value/Unit

Instruction

1

Get current magnitude of shunt

O

A (RMS)

shuntID/Imag

2

Get current angle of shun

O

Degree

shuntID/Iang

3

Set/Get powers of shunt (profile)

I/O

kW

kVAr

shuntID/P

shuntID/Q

4

Set/Get status of shun

I/O

0: Disconnected

1: Connected

shuntID/status