Documentation Home Page ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Positive Sequence Shunt

On this page:

The positive sequence shunt is used in the positive sequence network.

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Source name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Bus

Name of the bus its connected to

a unique name

P (MW)

Active power

MW

Q (MVAr)

Reactive power

MVAr

Available I/O Pins

No

Pin Description

Pin Type

Value/Unit

Instruction

No

Pin Description

Pin Type

Value/Unit

Instruction

1

Get current magnitude of shunt

O

A (RMS)

shuntID/Imag

2

Get current angle of shun

O

Degree

shuntID/Iang

3

Set/Get powers of shunt (profile)

I/O

kW

kVAr

shuntID/P

shuntID/Q

4

Set/Get status of shun

I/O

0: Disconnected

1: Connected

shuntID/status



OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323