Documentation Home Page Specialized Solutions Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Connection between OPAL-RT’s simulator and OP8660 conditioning module

OPAL-RT’s simulators compatible with the RCP-EC2K kit offer in their back and front panels access to a broad array of IO ports which can be flexibly customized and assigned as needed by the user. However, the RCP-EC2K kit has been conceived to allow users to quickly interface the OPAL-RT simulator with the OP8660 signal conditioning module.

Interfacing the OPAL-RT simulator with the OP8660 is straightforward: the compatible DB-37 connectors of both the simulator and the OP8660 are clearly identified with matching Quick Connection labels that must be connected using the provided DB-37 cables, as shown in Figure 3.1 for the OP56001. Table 3.1 indicates the connections to be performed and the signals contained on each connector.

Connections between OPAL-RT’s simulator and the OP8660 modules

OP8660

Standard label

Quick connection label present both in the simulator (OP5600/OP4510*/OP7000) and

the OP8660

 

Signals

C1

DO (1.B for OP4510)

Extra Digital Outputs:

Ø  DO1 through DO8

 

 

C2

 

 

DI (1.A for OP4510)

Extra Digital Inputs

Ø  DI1 through DI8 Two ABZ encoders:

Ø  ABZX1

Ø  ABZX2

 

C3

 

EI-1 (2.A for OP4510)

Voltage measurements:

Ø  E1 through E8 Current measurements:

Ø  I1 through I8

 

C4

 

EI-2 (2.B for OP4510)

Voltage measurements:

Ø  E9 through E16 Current measurements:

Ø  I9 through I16

 

 

C5

 

 

IFP (1.B for OP4510)

Inverter Firing Pulses:

Ø  IFP1 through IFP6 (Inverter 1)

Ø  IFP7 through IFP12

(Inverter 2)

C6

Not connected

Not connected

C7

AI (Not connected for OP4510)

Extra Analog Inputs:

Ø  AI1 through AI16

C8

AO (Not connected for OP4510)

Extra Analog Outputs:

Ø  AO1 through AO16

1 Depending on the specific system configuration and IO availability in the simulator, some of the signal depicted in Table 3.1 may or may not be available

Figure 3.1 Typical connection between the back panels of an OPAL-RT OP4510 simulator and the OP8660 module. Connection is straightforward using the matching connection labels.