The current and voltage measure elements are used to measure the current and voltage of network buses and to connect voltage or current output to HYPERSIM® control blocks.

The following table shows the various elements and parameters.

DescriptionElementInputOutputParameters: NameParameters 1.init.vaFunction and Conditions
Measures three-phase voltages

B

a

b

c

Ga

Gb

Gc

1.0

1.0

1.0

Measures voltages Va, Vb, Vc of bus B

a = Va * Ga

b = Vb * Gb

c = Vc * Gc

Measures three-phase currents

B1

B2

a

b

c

Ga

Gb

Gc

Rprobe

1.0

1.0

1.0

1.0e-3

Measures currents Ia, Ib, Ic flowing from B1 to B2 by inserting a resistance R

a = Ia * Ga

b = Ib * Gb

c = Ic * Gc

Measures single-phase voltages

By

G

1.0

Measures voltage B of bus C

y = V * G

Measures single-phase currents

B1

B2

y

G

Rprobe

1.0

1.0e-3

Measures currents I flowing from B1 to B2 by inserting a resistance R

y = I * G