Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Current and Voltage Measure Elements
The current and voltage measure elements are used to measure the current and voltage of network buses and to connect voltage or current output to HYPERSIM® control blocks.
The following table shows the various elements and parameters.
Description | Element | Input | Output | Parameters: Name | Parameters 1.init.va | Function and Conditions |
---|---|---|---|---|---|---|
Measures three-phase voltages | B | a b c | Ga Gb Gc | 1.0 1.0 1.0 | Measures voltages Va, Vb, Vc of bus B a = Va * Ga b = Vb * Gb c = Vc * Gc | |
Measures three-phase currents | B1 B2 | a b c | Ga Gb Gc Rprobe | 1.0 1.0 1.0 1.0e-3 | Measures currents Ia, Ib, Ic flowing from B1 to B2 by inserting a resistance R a = Ia * Ga b = Ib * Gb c = Ic * Gc | |
Measures single-phase voltages | B | y | G | 1.0 | Measures voltage B of bus C y = V * G | |
Measures single-phase currents | B1 B2 | y | G Rprobe | 1.0 1.0e-3 | Measures currents I flowing from B1 to B2 by inserting a resistance R y = I * G |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323