Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Current and Voltage Measure Elements

The current and voltage measure elements are used to measure the current and voltage of network buses and to connect voltage or current output to HYPERSIM® control blocks.

The following table shows the various elements and parameters.

DescriptionElementInputOutputParameters: NameParameters 1.init.vaFunction and Conditions
Measures three-phase voltages

B

a

b

c

Ga

Gb

Gc

1.0

1.0

1.0

Measures voltages Va, Vb, Vc of bus B

a = Va * Ga

b = Vb * Gb

c = Vc * Gc

Measures three-phase currents

B1

B2

a

b

c

Ga

Gb

Gc

Rprobe

1.0

1.0

1.0

1.0e-3

Measures currents Ia, Ib, Ic flowing from B1 to B2 by inserting a resistance R

a = Ia * Ga

b = Ib * Gb

c = Ic * Gc

Measures single-phase voltages

By

G

1.0

Measures voltage B of bus C

y = V * G

Measures single-phase currents

B1

B2

y

G

Rprobe

1.0

1.0e-3

Measures currents I flowing from B1 to B2 by inserting a resistance R

y = I * G