Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Description

The 2-winding linear transformer is the simplest form of 1-phase transformer. It is best used when the simulation of saturation can be avoided as it can save computation time.

Table of Contents

Mask and Parameters

General Parameters

DescriptionUse this field to add all kinds of information about the component
Base primary/secondary winding voltage (rmsLN)Base value pour PU conversion (kV)
Base power (total)Base value pour PU conversion (MVA)
Base frequencyBase value pour PU conversion (Hz)

Magnetization Impedance Parameters

RmEquivalent resistance of iron losses of the magnetic circuit (Ω)
LmMagnetization inductance (H)

Winding Parameters

Voltage (rmsLN)Rated voltage of the winding (kV)
R1, R2Leakage resistance of the winding (Ω)
L1, L2Leakage inductance of the winding (H)

Ports, Inputs, Outputs and Signals Available for Monitoring

Ports

Net_1+Positive primary winding connection (supports only 1-phase connections)
Net_1-:Negative primary winding connection (supports only 1-phase connections)
Net_2+Positive secondary winding connection (supports only 1-phase connections)
Net_2-Negative secondary winding connection (supports only 1-phase connections)

Inputs

  • None

Outputs

  • None

Sensors

ILMAGMagnetization current (A)
IPRIMPrimary current (A)
ISEC2Secondary current (A)
  • No labels