Accessing the I/O Interface Configuration

The Signal Generator protocol can be configured in the I/O Interface Configuration tool that is opened from the HYPERSIM ribbon.

  • For more information on the general use of the I/O Interface Configuration, see here.
  • For more information on the configuration of the I/O Connection, see here.

General Configuration

The Signal Generator driver is configured through several pages. The first page contains generic configuration.

Record driver dataSelect this option to record all inputs/outputs of the signal generator driver.
Group by typeSelect this option to group recorded data by signal type.
  • Any number of each signal type can be added.
  • Signal Waves (with the exception of Time Signal) have almost the same type and number of input parameters: Frequency, Amplitude, Phase, and Offset.
  • The square wave has an additional parameter: Duty Cycle.
  • These parameters can be edited while the simulation is running but connections have to be made between the driver data point and the model data point to make it work. All signals can be displayed in ScopeView.

Supported Signals

Sawtooth Waves

To add a signal, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected Signal.

The arrow next to each button provides more options (duplicate signals and/or add multiple signals at once).

You can remove one or several signals, or reorder them by using the arrow buttons.

Signal NameName of the signal.
AmplitudeAmplitude of the signal.
Frequency (Hz)Frequency of the signal in Hertz.
Offset

Sine Waves

To add a signal, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected Signal.

The arrow next to each button provides more options (duplicate signals and/or add multiple signals at once).

You can remove one or several signals, or reorder them by using the arrow buttons.

Signal NameName of the signal.
AmplitudeAmplitude of the signal.
Frequency (Hz)Frequency of the signal in Hertz.
Phase (radians)Phase of the signal in radians
Offset

Square Waves

To add a signal, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected Signal.

The arrow next to each button provides more options (duplicate signals and/or add multiple signals at once).

You can remove one or several signals, or reorder them by using the arrow buttons.

Signal NameThe name of the signal.
AmplitudeAmplitude of the signal.
Frequency (Hz)Frequency of the signal in Hertz.
Offset
Duty Cycle (%)It determines the amount of time the square signal is active.

Triangular Waves

To add a signal, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected Signal.

The arrow next to each button provides more options (duplicate signals and/or add multiple signals at once).

You can remove one or several signals, or reorder them by using the arrow buttons.

Signal NameThe name of the signal.
AmplitudeAmplitude of the signal.
Frequency (Hz)Frequency of the signal in Hertz.
Offset

Oprec Files

To input an .oprec file in HYPERSIM, you must create it via the datalogger. See Datalogger section for more information on the generation.

To add a file, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected File.

The arrow next to each button provides more options (duplicate files and/or add multiple files at once).

You can remove one or several files, or reorder them by using the arrow buttons.

To configure the I/O interface, paste the absolute path of your .oprec file, and select Repeat mode if needed.

File PathAbsolute path to your .oprec file. it must in the same directory as your model.ecf file.
Repeat modeAllows you to repeat the value you set up in your .oprec file while the simulation is running.

CSV Files

To input a .csv file in HYPERSIM, you must create a file with specific formatting (shown below) and make sure you saved the .csv file at the same location than your model (.ecf)

In the example below, we are using three inputs (time, s1 and s2). time is going from 0 to 0.03 with an increment of 0.01.

Each piece of data must be separated by a semicolon (;)

To add a file, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected File.

The arrow next to each button provides more options (duplicate files and/or add multiple files at once).

You can remove one or several files, or reorder them by using the arrow buttons.

To configure the I/O interface, paste the absolute path of your .csv file, and select Repeat mode if needed.

File PathAbsolute path to your .csv file. it must in the same directory as your model.ecf file.
Repeat modeAllows you to repeat the value you set up in your .csv file while the simulation is running.

File.csv example

Time Signal

To add a signal, click any of the Add 1 item buttons, depending on if you want to add it Above or Below the selected Signal.

The arrow next to each button provides more options (duplicate signals and/or add multiple signals at once).

You can remove one or several signals, or reorder them by using the arrow buttons.

This type of signal is used to replace...:

Signal NameName of the signal.
Format

Format of the signal. Only Epoch time is supported.

Epoch date and time from which system time is measured. Number of seconds elapsed since 00.00.00 January 1st, 1970.

On a Linux machine, it can be obtained using the following command: date +%s


Monitoring the Results in ScopeView

Due to the fact that ScopeView monitors the simulation regardless of where the simulation actually is, the starting value might differ depending on when you click on play in acquisition.

Further information on ScopeView available at this link .