To migrate a VeriStand project to a newer version of the Power Electronics Add-On it is necessary to follow a series of steps. When upgrading a project from an older version to a more recent one, follow the adequate steps listed below. Some steps are duplicated, in that case the duplicated steps should be skipped.
Migrating from 1.14.X to 1.15.0
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If a window opens asking for files to be relinked, click Skip. The files will automatically be relinked by the system definition update process.
Save and close the System Definition.
Verify IO Channel Mapping
The names of the channels for all the IO in the Power Electronics Addon has been modified to match the IO nomenclature used by NI. DIO channels are now named ConnX.DIOXX, AI channels are now named ConnX.AIXX, and AO channels are now named ConnX.AOXX. After migrating a project from a previous version of the Power Electronics Addon, it is recommended to
Relink all IO channels used in the VeriStand UI manager
Relink all IO channels used in the System Configuration Mapping page of the VeriStand project
Verify that all IO mappings that were configured in the Power Electronics Addon are still valid (ex. on the Sources, Switches, Digital Outputs, and Resolver pages)
Your project should now be compatible with version 1.15.0.
Migrating from 1.14.0 to 1.14.1
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If a window opens asking for files to be relinked, click Skip. The files will automatically be relinked by the system definition update process.
Save and close the System Definition.
Follow the steps listed in Migrating from 1.14.X to 1.15.0.
Your project should now be compatible with version 1.14.1.
Migrating from 1.13.X to 1.14.0
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If a window opens asking for files to be relinked, click Skip. The files will automatically be relinked by the system definition update process.
Save and close the System Definition.
Follow the steps listed in Migrating from 1.14.0 to 1.14.1.
As of version 1.14.0, the Power Electronics Add-On now requires MATLAB Runtime version R2018b (9.5). Make sure to install this newer version of the run-time here before deploying a VeriStand project.
Your project should now be compatible with version 1.14.0.
Migrating from 1.13.0 to 1.13.1
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If a window opens asking for files to be relinked, click Skip. The files will automatically be relinked by the system definition update process.
Save and close the System Definition.
Follow the steps listed in Migrating 1.13.X to 1.14.0.
Your project should now be compatible with version 1.13.1.
Migrating from 1.12.X to 1.13.0
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If a window opens asking for files to be relinked, click Skip. The files will automatically be relinked by the system definition update process.
Ensure that all the elements in the Sources and Switches pages have valid mapping elements selected. If they do not all have valid mapping selections, an error will be thrown at deployment.
Expand any machines in the project and navigate to each of their Resolver and Encoder pages. If the Number of Pole Pairs parameter is set to 0, update it to 1 or another nonzero value. Any machine sensor configured to have 0 pole pairs will cause an error to be thrown at deployment.
Save and close the System Definition.
Follow the steps listed in Migrating from 1.13.0 to 1.13.1.
Your project should now be compatible with version 1.13.0.
Target Update
As of version 1.13.0 of the Power Electronics Add-On, the Real Time target is required to have the FlexRIO driver installed, in addition to the NI VeriStand Engine. Please see the Deployment Target Software Requirements page for additional information and installation instructions.
As of version 1.13.0, the Phar Lap operating system is no longer supported in the Power Electronics Add-On. If using a Real Time target running the Phar Lap operating system, the following options are available:
Migrating the Real Time target to the Linux RT operating system. For assistance with this process, refer to Provisioning a PXIe Controller to the NI Linux Real-Time Operating System and contact NI Support if needed.
Using version 1.12.0 of the Power Electronics Add-On for VeriStand 2018.
Not migrating to a new version of the Power Electronics Add-On and continuing to use the test system in its current state.
Migrating from 1.11.X to 1.12.0
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If a window opens asking for files to be relinked, click Skip. The files will automatically be relinked by the system definition update process.
Ensure that all the elements in the Sources and Switches pages have valid mapping elements selected. If they do not all have valid mapping selections, an error will be thrown at deployment.
In the Waveforms and Analog Outputs pages, identify any elements set to <Machine Name>.Mechanical Angle (Deg). Use the drop-down arrow for an element to update its value to <Machine Name>.Mechanical Angle (Turn).
Save and close the System Definition.
Follow the steps listed in Migrating from 1.12.X to 1.13.0.
Your project should now be compatible with version 1.12.0.
Migrating from 1.10.X to 1.11.0
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
Save and close the System Definition.
Follow the steps listed in Migrating from 1.11.X to 1.12.0.
Your project should now be compatible with version 1.11.0.
Migrating from 1.9.X to 1.10.0
Project Dependency Update
Open the System Definition of the existing project. This will automatically trigger a dependency update.
Save and close the System Definition.
Follow the steps listed in Migrating from 1.10.X to 1.11.0.
Your project should now be compatible with version 1.10.0.
Migrating from 1.8.X to 1.9.0
Project Dependency Update
When a VeriStand project created in a previous version of the Add-on is opened for the first time, a prompt is shown to the user stating that that the following files are missing on disk:
eHSx64_IM_IO_7868R.lvbitx
hardware_configuration.json
In the prompt, click the Skip button for both dependencies and Save the project.
Open the System Definition of the existing project. This will automatically trigger a dependency update.
If using a PMSM BLDC machine configured in Variable Ld/Lq mode, follow the steps described in the next section.
Save and close the System Definition.
Follow the steps listed in Migrating from 1.9.X to 1.10.0.
PMSM BLDC JSON File Update
If using the PMSM BLDC machine model configured to use the Variable Ld/Lq motor type, the JSON file must be updated to include the DqTransformAngleOffset parameter.
Open the existing JSON parameter file in a text editor.
Add a new line under "PolePairs": and enter the following text: "DqTransformAngleOffset": 0
For more information about this parameter, see the JSON Motor Model File description.
Save the JSON file.
Your project should now be compatible with version 1.9.0.
Migrating from 1.7.X to 1.8.0
Project Dependency Update
When a VeriStand project created in a previous version of the Add-on is opened for the first time, a prompt is shown to the user stating that that the following files are missing on disk.
In the prompt, click on the Skip button for both dependencies and Save the project.
Open the System Definition of the existing project. This will automatically trigger a dependency update.
Save and close the System Definition.
Depending on the hardware configuration used by your project, follow the steps described in the next sections.
Follow the steps listed in Migrating from 1.8.X to 1.9.0.
PMSM BLDC Machines
If using one the following hardware configurations:
Dual_eHSx64_Quad_PMSM_VDQ_IO_Dual_7868R
eHSx64_Dual_PMSM_VDQ_IO_7868R
Open the System Definition of the existing project.
Browse through the System Definition Tree and expand each PMSM VDQ section in the hardware configuration.
Rename each PMSM VDQ page to PMSM BLDC for consistency.
If the Digital Outputs, Analog Outputs, or Waveforms pages contain elements mapped to PMSM VDQ channels, use the drop-down arrow for each element to update its mapping to PMSM BLDC.
Save the System Definition.
Hall Effect Pages
If using one of the following hardware configurations:
Dual_eHSx64_Quad_PMSM_VDQ_IO_Dual_7868R
eHSx64_Dual_PMSM_VDQ_IO_7868R
eHSx32_Dual_PMSM_SH_IO_7868R
Open the System Definition of the existing project.
Navigate to the Hall Effect page under each machine.
Remove all Hall Effect pages from the System Definition tree.
VeriStand will open three different dialog windows specifying that error 36 has occurred (this will occur for each Hall Effect sensor removed). This is expected behavior due to removing the sensor. If these pages are not removed manually, the user will see an error upon deployment.
Save the System Definition.
PMSM SH Machines
When using the following hardware configurations:
eHSx32_Dual_PMSM_SH_IO_7868R
eHSx128_Dual_PMSM_SH_IO_7976R
Open the System Definition of the existing project.
Navigate to one of the two PMSM SH pages.
Update the Sample time parameter to 4E-7 (400ns). This will update the parameter for both machines.
Save the System Definition.
Your project should now be compatible with version 1.8.0.
Migrating from 1.6.X to 1.7.0
This procedure is required when upgrading a VeriStand project created in the 1.6.X version of the Power Electronics Add-On.
Open the System Definition of the existing project. Automatically, an upgrade process of the system definition tree will be executed.
Note: This process will generate a backup of the entire folder where the VeriStand project is saved. The backup will get stored in a zip file located in the project directory.If a Window opens asking for files to be relinked, click on the Skip option (the files will automatically be relinked by the system definition updated process)
Browse through the System Definition Tree and click on the Circuit Model section of each circuit in the hardware configuration.
Click on the Reload button.
Save the System Definition.
Follow the steps listed in Migrating from 1.7.X to 1.8.0.
Your project should now be compatible with version 1.7.0.