Supported Features

  • Standard registers:
    • Coils: Available as a model output, a model input (controlled by the master) or both
    • Discrete inputs: Available as a model output
    • Input registers: Available as a model output. The supported data types are UINT16, INT16, UINT32, INT32 and FLOAT32.
    • Holding registers: Available as a model output, a model input (controlled by the master) or both. The supported data types are UINT16, INT16, UINT32, INT32 and FLOAT32.
  • TCP and RTU modes
  • Allows multiple slaves instantiation
  • Configurable TCP port when operating over TCP mode
  • Configurable serial port parameters when operating over RTU mode
  • Supports reconnection with master device(s) if a connection is lost
  • TCP mode supports connecting multiple masters to the same slave

Limitations

  • Modbus ASCII is not supported
  • A BlueStorm RS-485 card is needed in case it is required to communicate with multiple slaves on the same physical bus in RTU mode