Documentation Home Page Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

GENERAL

Product Name

32 Channels High-Range DIO

Part numbers

OP5369

Board type

Digital input/output conditioning

Form factor

Mezzanine Type B

Dimensions

6.60 cm x 12.50 cm (2.6” x 4.92”)

Hot-Plug support

No

Characteristic

Number of channels

32 IO in 4 Banks configurable as inputs or outputs  Bank1 : D0-7    Bank2 : D8-15   Bank3 : D16-23     Bank4 : D24-31

VUser1 for Bank 1 and 2      VUser2 for Bank 3 and 4

INPUT DIRECTION

Input impedance

> 100 kOhm

Reverse voltage protection

Diode

Maximum  voltage protection

+/- 50 Volts

Detection threshold

4 programmable Schmitt trigger level step 0.118V from 0.470V to 29.4V threshold high and threshold low for each bank

Recommended levels threshold

The default thresholds are LOW = 1.5V, HIGH = 3.5V.

To improve noise immunity, a LOW level threshold of 1/3 VUser and a HIGH level threshold of 2/3 VUser are recommended.

Voltage range

0 to 30 Vdc

Delay Low-to-High

10 ns (implementation-dependent)                                                         

Delay High-to-Low

15 ns (implementation-dependent)                                                        

OUTPUT DIRECTION

Output protection

50 mA resettable fuse

Output impedance2 to 15 Ohm

Protection thresholds

Maximum VUser + 0.5V

Minimum  -0.5V

Output voltage range

4.5 to 25Vdc Max (default internal 4.5 volts)

Logic high levels (typical) 

No load:  VUser -0.2V   

50mA :     VUser -0.9V (in OP5XXX system)    

Logic low levels (typical) 

No load:  0.1V 

50 mA:     0.9V (in OP5XXX system)

Output configuration

Push-pull 

Delay Low-to-High (typical value, implementation-dependent)

< 100ns @25°C for  25V 

< 90ns @25°C for 5 V                                      

Delay High-to-Low (typical value, implementation-dependent)

< 100ns @25°C for  25V

< 90ns @25°C for 5 V                                       

Rise / Fall time

< 40ns,   < 50ns                                   

Minimum pulse detection (resolution)

90 ns   5V

130 ns  30V

Output frequency

DC to 4MHz (see table below)

Environmental


 

The OP5369 is designed for indoor use only.

Module operating temperature

0 °C to 40 °C

Storage temperature

-40 °C to 85 °C

Operating humidity

10% to 90% non-condensing

Storage humidity

5% to 95% non-condensing

Pollution degree

2

Maximum altitude

2,000 m

Power requirement15W

Maximum PWM Output Frequency for Given Number of Repetitive Signals


OP5650/OP5x07/OP5705/OP4610OP4510
Vuser / Channel

<=25V

<=12V<=5V<=25V<=12V<=5V
1 1 MHz2 MHz4 MHz16 kHz **2 MHz4 MHz
5 1 MHz2 MHz4 MHz16 kHz **1 MHz4 MHz
150.3 MHz **2 MHz4 MHz16 kHz **0.5 MHz2 MHz
320.3 MHz **1 MHz4 MHz16 kHz **0.5 MHz1 MHz
**0.5 MHz if T amb <= 25°C

  • No labels