Documentation Home Page ARTEMiS Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

The native saturable transformer model of SPS has no linear part in its magnetization branch. The magnetization branch is instead modeled entirely by a current injection. The current injection is computed from a table of the phi=f(i), with the flux being computed from the integral of voltage across the magnetization branch.

In the SPS model, the non-linear Lsat component of the transformer is completely modeled by a current injection computed from the phi=f(i) characteristics.

In SPS in particular, one can specify a residual flux only when the segment 1-2 has infinite slope as mentioned in the SPS documentation.

  • No labels