Documentation Home Page Power Electronics Add-On for NI VeriStand Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Sinewave Generators

Next, we can configure the Sinewave Generators used in the simulation.

  • In the Configuration Tree, expand Circuit Model >> Sinewave Generators 

  • Configure the Sinewave Generators by confirming that the Default Value of each relevant channel is configured as shown in the table below.

  • Click Save.


Frequency Engines

Channel Name

Default Value


Frequency Engine 0

60Hz
SWG 0

Channel Name

Default Value


Frequency Engine0

Phase
SWG 1

Channel NameDefault Value

Frequency Engine0

Phase-120º
SWG 2

Channel NameDefault Value

Frequency Engine0

Phase120º

The default value of the Phase channel of SWG 1 is set to -120.  The default values for the other channels listed above can be configured in a similar manner.

SPWM Generators

Error rendering macro 'excerpt-include' : No link could be created for '2.6 Setting Default Values for the SPWM Generators'.


SPWM Carrier

Channel Name

Default Value


Carrier Frequency

5000Hz
SPWM Generator 0

Channel Name

Default Value


Frequency Engine0

Phase
SPWM Generator 1

Channel NameDefault Value

Frequency Engine0

Phase-120º
SPWM Generator 2

Channel NameDefault Value

Frequency Engine0

Phase120º
SPWM Generator 3

Channel Name

Default Value


Frequency Engine0

Phase30º
SPWM Generator 4

Channel NameDefault Value

Frequency Engine0

Phase-90º
SPWM Generator 5

Channel NameDefault Value

Frequency Engine0

Phase150º


The default value of the Phase channel of SPWM Generator 1 is set to -120.  The default values for the other channels listed above can be configured in a similar manner.