Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Block

Mask

Description

This Analog In functionality block, OpFcnAnalogIn, is used to return acquisition data obtained from the analog input channels of an OP5340 module installed on an OP5130 board.

Parameters

ControllerNameEach functionality block such as the OpFcnAnalogIn block must refer to an OpCtrl block such as the OP5130 Ctrl block, that will manage the data transfer with the IO board. The binding between OpFcn and OpCtrl blocks is performed via the use of the Controller name that each OpCtrl block uniquely defines. This binding is checked during the initialization phase of the model. If no OpCtrl block is found that defines the same Controller Name as this OpFcnAnalogIn block, the OpFcnAnalogIn block is simply disabled and returns 0s.
Selection of ChannelsThe block will output to the model the acquisition values of the channels listed here. With the OP5130board, the channels numbers are organized as follows: channels 0to 15 of module A are identified as [0:15], while channels 0 to 15of module B are identified as [1000:1015].
Sample Time (s)This parameter allows the user to specify the block sample time in seconds. The default value is 0, which specifies a continuous sample time (note that the sample time is borrowed from the separated subsystem) while -1 specifies an inherited sample time. A functionality block and its associated controller block must execute at the same sample time.

Inputs

This block has no inputs.

Outputs

This output returns the acquisition data, in Volts, from the channels specified in the mask parameter.

Characteristics and Limitations

Connector Pin Assignments:

The user should refer to the documentation of the IO board that holds the AnalogIn module, such as the OP5130 board, for connector pin assignments.

Direct FeedthroughNo
Discrete sample timeYes
XHP supportYes
Work offlineNo
  • No labels