Block
Mask
Description
This block recovers the data from a digital out Interface block and generates the signals needed by the DataOut block.
Parameters
This block has no parameters.
Inputs
Sync | This signal is the synchronization pulse train. It is usually connected to the ModelSync signal. |
---|---|
Ton[X] where X=[0,7] | This signal is the 14-bit wide Time-On value, corresponding to the total on time, in clock ticks. |
Status[X] where X=[0,7] | This signal represents the logic level of the input at the end of the preceding time step. |
Fault[X] where X=[0,7] | This signal represents an error flag. |
Outputs
DataOut | This signal contains the data of a digital subsection and a valid bit. It is meant to interface the DataOut block. |
---|---|
DataSync | This signal represents a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block corresponding to the channel selected for the DataOut signal. |
Characteristics and Limitations
This Block has no specific characteristics or limitations.