Block
Mask
Description
This block recovers the data from an SSI Master Interface block and generates the signals needed by the DataOut block.
Parameters
This block has no parameters.
Inputs
PositionValue | 64 bits position value received from the SSI Master. |
PositionValue_valid | Valid flag indication that data present on PositionValue port is valid. |
Outputs
DataOut | This signal contains a valid bit and the serialized position value received from the SSI Master block. It is meant to interface the DataOut block. |
DataSync | This signal represents a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block corresponding to the channel selected for the DataOut signal. |
Characteristics and Limitations
This Block has no specific characteristics or limitations.
Block
Mask
Description
This block recovers the data from an SSI Master Interface block and generates the signals needed by the DataOut block.
Parameters
This block has no parameters.
Inputs
PositionValue | 64 bits position value received from the SSI Master. |
PositionValue_valid | Valid flag indication that data present on PositionValue port is valid. |
Outputs
DataOut | This signal contains a valid bit and the serialized position value received from the SSI Master block. It is meant to interface the DataOut block. |
DataSync | This signal represents a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block corresponding to the channel selected for the DataOut signal. |
Characteristics and Limitations
This Block has no specific characteristics or limitations.