The OP8662 provides banana jacks to interface with monitoring devices.
OP8662-4-300 and OP8662-4-600
OP8662-8-300 and OP8662-8-600
A | Power switch and indicator |
B | Ground connector |
C | High current probe connectors (maximum 15 A AC), with red and green LEDs to indicate channel activity. - Green LED: "On" if there is activity on the channel, and "Off" if there is no activity on the channel.
The LED will light up if it reads at least 5% of the maximum rated value, i.e., 0.75 A for all models
- Red LED: Indicate an overcurrent on the channel.
The LED will light up if it reads 105% or more of the maximum rated value, i.e. 15.75 A for all models.
|
D | High-voltage probe connectors (maximum 300 or 600 V), with red and green LEDs to indicate channel activity. - Green LED: "On" if there is activity on the channel, and "Off" if there is no activity on the channel.
The LED will light up if it reads at least 5% of the maximum rated value, i.e.- 15 V for 300 V models
- 30 V for 600 V models
- Red LED: Indicate an overvoltage on the channel.
The LED will light up if it reads 105% or more of the maximum rated value, i.e.- 315 V for 300 V models
- 630 V for 600 V models
|