  • Xls: Armature leakage reactance (pu);
  • Xmd: Direct magnetizing reactance (pu);
  • Xmq: Quadrature magnetizing reactance (pu);
  • Xlkq1: Quadrature damper winding 1 leakage reactance (stator side) (pu);
  • Xlkq2: Quadrature damper winding 2 leakage reactance (stator side) (pu);
  • Xlfd: Field winding leakage reactance (stator side) (pu);
  • Xlkd: Direct damper winding leakage reactance (stator side) (pu);
  • Rs: Armature resistance (pu);
  • Rkq1: Quadrature damper winding 1 resistance (stator side) (pu);
  • Rkq2: Quadrature damper winding 2 resistance (stator side) (pu);
  • Rfd: Field winding resistance (stator side) (pu);
  • Rkd: Direct damper winding resistance (stator side) (pu);
  • Rg: Neutral connection resistance (pu);
  • H: Inertia constant (pu.s);
  • F: Friction constant (pu);
  • P: Number of poles;
  • N_slot: Number of stator slots;
  • N_cs: Number of conductors per slot;
  • N: Number of parallel windings per phase; Winding functions for complete phase and each individual windings.