The OP4610-IO can hold any combination of four of the following Type B mezzanines. The standard configuration contains one of each.

Compatible I/O modules and suggested standard configuration

The OP4610-IO can hold any combination of four (4) compatible I/O modules.

This default I/O module configuration suggested comprises:

2x OP5330 - 16 Analog Output at 1MSPS or 8 Analog Output at 2MSPS
1x OP5342 - 16 Analog Input - 2MSPS
1x OP5369 32-Channel Digital IO Board

RS-422 Digital In

Number of channels

6 differential inputs

Detection threshold

± 0.2 V (for ± 7 V range)

± 0.5 V (for ± 15 V range)

Input current

± 3 mA

Voltage range

5 Vdc

Delay Low-to-High

65 ns

RS-422 Digital Out

Number of channels

6 differential outputs

High level (With load) Low level (With load)

2.5 V min @ -20 mA

0.5 V max @ 20 mA

Voltage range

5 Vdc

Delay Low-to-High

55 ns

  • No labels