Group

Model Configuration, Acquisition
Description

Sets the decimation factor to use when getting data for the specified acquisition group. The change is persistent and is used in subsequent runs of the model.

Required Control

Acquisition Control
Usage

RtlabApi.SetDecimationFactor(acqGroup, decimationFactor)

Input
  • acqGroup: Acquisition group (numbering starts at 0).
  • decimationFactor: Value of the decimation factor to set for the specified acquisition group.

Output

None

Exception
  • EPERM: System control had not been granted to this client.
  • EINVAL: invalid acquisition group or specified decimation factor is out of range.
  • EBADF: Model not specified by previous Connect or SetCurrentModel.
  • EIO: Error sending the request or receiving the reply.
  • EFAULT: Warning: Time factor differs from 1.0.
  • EACCES: Error saving parameters to .probe file.
  • OP_API_MODEL_IO_TIMEOUT: Timed out waiting for a reply from the model.
  • OP_API_MODEL_IO_ERROR: Model is missing some or all processes or subsystems.
ExamplesNone
Related ItemsSetFillDecimation
Modulesimport RtlabApi
  • No labels