Group

Model Interaction, Original Model
Description

Loads the original model (block diagram) of the current connected model on the client machine. Furthermore, if the model is a Simulink model, the client machine must have Matlab installed.

Required Control

None
Usage

RtlabApi.LoadOriginalModel()

Input

None

Output

None

Exception
  • EOK: Success.
  • EINVAL: not a Simulink model.
  • EIO: Error sending the request or receiving the reply.
  • EBADF: Model not specified by previous Connect or SetCurrentModel.
  • ENOENT: the model path and/or name is NULL.
  • EDOM: model version is different from Simulink version.
  • ERANGE: model version is not compatible with MATLAB version.
ExamplesNone
Related ItemsIsOriginalModelOpen, ResetOriginalModel
Modulesimport RtlabApi
  • No labels