Page Content
Rear Panel Description
Power cord plug and master power on/off switch
4x DB37 I/O connectors for I/O module in slot 1
4x DB37 I/O connectors for I/O module in slot 2 (optional)
Ground screw
Please see Connecting the Ground Screw page in these pages
RS-422 DB9 connectors with 6 Rx and 6Tx
This is the default configuration. See below for other options available.
See here OP5969-1 RS422 Digital Inputs and Outputs (DIO) for specifications and pin assignments.
PCI Express Gen 2 x4 port:
This port is used to connect the FPGA in the OP4810-IO/OP4815-IO to another compatible OPAL-RT’s simulator.
The other device must have a OneStop communication card installed. See the Use Cases page in this section.
The I/O modules are factory installed and must be selected at ordering.
I/O Module Slots
Up to 2 I/O modules (or IO boards) can be installed in one of the two slot locations of an OP4810-IO or OP4815-IO FPGA Processor and I/O Expansion unit.
Slots are identified Slot 1 and Slot2.
If only one I/O module is installed, it is installed in slot 1.
A second optional I/O module can be installed in slot 2.
I/O Module (or IO Board)
I/O Module (IO Board) Identification
Module models are identified OP48Hxx, where “xx” is a number.
See available I/O modules here: OP48H00 I/O Modules Series for OP4800 Line of Devices
SLOT x can be SLOT 1 or SLOT 2
Each I/O modules provides four (4) DB37 connectors numbered P1 to P4. Each port is labeled with the type of IO:
Digital input (Din)
Digital output (Dout)
Analog input (Ain)
Analog output (Aout)
The pin assignments for each channel depend on the type of module. They are described in the System Description Document delivered with the unit.
See also pin assignments here: OP48H00 I/O Modules Series for OP4800 Line of Devices.
The I/O modules are factory installed and must be selected at ordering.
Example
In this example:
The I/O card model OP48H10 is installed in slot 1 of the unit (leftmost slot when facing the back of the device)
Connector P1 and P2 include 32 digital inputs or outputs (Dio) numbered from channel 0 to channel 31
DIOs can be configured as inputs our outputs by groups of 8 (4 banks of 8 IOs)
Connector P3 includes 16 analog outputs (Aout) identified channel 0 to channel 15
Connector P4 includes 16 analog inputs (Ain) identified channel 0 to channel 15
Default I/O Module Configuration Suggested
Another OP48H10 Fast I/O, type H module can be installed optionally.
Standard and Optional I/O Connectors
The OP4810-IO/OP4815-IO comes with an RS-422 Connector Kit (OP5969-1) factory installed by default.
The optional Fiber-Optic Connector Kit (OP5969-2) can also be installed. It will replace the default connector.
The optional Fiber-Optic Connector Kit must be selected at the time of purchase and factory-installed.
RS422 connector kit | It is the default I/O module provided with the OP4810-IO/OP4815-IO. | |
---|---|---|
Fiber-Optic connector kit | The default RS422 I/O module above provided with the OP4810-IO/OP4815-IO can be replaced by this fiber-optic module. |
Side Access Panel
The side access panel located on the left side of the device is reserved for OPAL-RT.