Machine controller data come from ElmDsl sections in the DGS-XML file.

These PowerFactory components are mapped to the components of the Native Library.

The version of the ElmDsl components can be determined using the following pattern:

Version

Type Prefixes

 

 

PowerFactory 2022 and prior versions

Exciters: avr_

Governors: gov_

Stabilizers: pss_

Overexcitation limiters: oel_

Underexcitation limiters: uel_

 

 

PowerFactory 2023 and more recent versions

Exciters: exc_PSSE_

Governors: gov_PSSE_

Stabilizers: pss_PSSE_

Overexcitation limiters: oel_PSSE_

Underexcitation limiters: uel_PSSE_

  • Up to v2020.4, it was possible to use FMU library with PowerFactory input files to cover a wider range of the control models. This feature has been disabled in the current release.

  • The remote bus feature is also not supported in stabilizers with PowerFactory input files.

  • Please refer to Mapping to PowerFactory parameters for more details about this disabled feature.