Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

List of Available Signals

At acquisition, the following signals are made available by sensors:

Ia,b,c_labelCurrent through the switch (PU)
cmd12,a,b,c_labelFiring command for the “1 to 2” component of the switch
cmd21, a,b,c_labelFiring command for the “2 to 1” component of the switch
state12, a,b,c_labelState of the “1 to 2” component of the switch
state21, a,b,c_labelState of the “2 to 1” component of the switch
FailSig,a,b,c_labelAlarm signal from the switch whose meanings are the following:
1Violation of the extinction time limit Tq for Thyristor12. (Automatically reset to zero after 1 calculation time step)
1Violation of the extinction time limit Tq for Thyristor21. (Automatically reset to zero after 1 calculation time step)
2Thyristor12 reverse voltage is higher than Rbov. (Reset only by Fail Reset=1)
2Thyristor21 reverse voltage is higher than Rbov. (Reset only by Fail Reset=1)
3Thyristor12 forward voltage is higher than Fbov. (Reset only by Fail Reset=1)
3Thyristor21 forward voltage is higher than Fbov. (Reset only by Fail Reset=1)
P_labelThe control signal from the Control System module.


Electronic Switches Command Panel

Electronic switches command panel



OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323