List of Available Signals

At acquisition, the following signals are made available by sensors:

Ia,b,c_labelCurrent through the switch (PU)
cmd12,a,b,c_labelFiring command for the “1 to 2” component of the switch
cmd21, a,b,c_labelFiring command for the “2 to 1” component of the switch
state12, a,b,c_labelState of the “1 to 2” component of the switch
state21, a,b,c_labelState of the “2 to 1” component of the switch
FailSig,a,b,c_labelAlarm signal from the switch whose meanings are the following:
1Violation of the extinction time limit Tq for Thyristor12. (Automatically reset to zero after 1 calculation time step)
1Violation of the extinction time limit Tq for Thyristor21. (Automatically reset to zero after 1 calculation time step)
2Thyristor12 reverse voltage is higher than Rbov. (Reset only by Fail Reset=1)
2Thyristor21 reverse voltage is higher than Rbov. (Reset only by Fail Reset=1)
3Thyristor12 forward voltage is higher than Fbov. (Reset only by Fail Reset=1)
3Thyristor21 forward voltage is higher than Fbov. (Reset only by Fail Reset=1)
P_labelThe control signal from the Control System module.


Electronic Switches Command Panel

Electronic switches command panel