Valve parameters

General parameters
Connection (series = Serial; delta = Delta);


Switch parameters

  • Switch type (Breaker, Ideal Switch, Thyristor,Diode, GTO+Diode): Specifies the valve type that makes the converter;
  • Signal reset (Enable, Disable): Reset the default signal to zero.
  • Precision valve (Active=Enable, Desactivated=Disable)

Specific parameters

  • Rbov (Reverse break overvoltage): Highest value of reverse voltage across a valve. Relevant only for diodes, thyristors and GTOs (volts);
  • Fbov (Forward break overvoltage): Highest value of reverse voltage across a blocked valve. Relevant only for diodes, thyristors and GTOs (volts);
  • C_snubber: Snubber capacitance (farads);
  • R_snubber: Snubber resistance (ohms);
  • Tq: Turn-off time (seconds);
  • Ibreak: GTO maximum breakable current (amperes);
  • Th Roff: Open state resistance (ohms);
  • Th Ron: Closed state resistance (ohms);
  • Vf1: Forward voltage drop (volts);
  • Ihold: Holding current.