Valve parameters
General parameters
Connection (series = Serial; delta = Delta);
Switch parameters
- Switch type (Breaker, Ideal Switch, Thyristor,Diode, GTO+Diode): Specifies the valve type that makes the converter;
- Signal reset (Enable, Disable): Reset the default signal to zero.
- Precision valve (Active=Enable, Desactivated=Disable)
Specific parameters
- Rbov (Reverse break overvoltage): Highest value of reverse voltage across a valve. Relevant only for diodes, thyristors and GTOs (volts);
- Fbov (Forward break overvoltage): Highest value of reverse voltage across a blocked valve. Relevant only for diodes, thyristors and GTOs (volts);
- C_snubber: Snubber capacitance (farads);
- R_snubber: Snubber resistance (ohms);
- Tq: Turn-off time (seconds);
- Ibreak: GTO maximum breakable current (amperes);
- Th Roff: Open state resistance (ohms);
- Th Ron: Closed state resistance (ohms);
- Vf1: Forward voltage drop (volts);
- Ihold: Holding current.