Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Speed Regulator | Programmable Parameters
Regvi_mod | Selection of speed regulator model. (Internal: actual model; External: model supply by user) |
---|---|
tb_r | Permanent droop (pu) |
tb_db | Dead band of speed regulator (pu) |
tb_k1 | Regulator gain (pu) |
tb_t1 | Time constant of speed relay (s) |
tb_t2 | Time constant os servo-valve (s). |
tb_pah1 | Upper limit of valve speed at opening, (absolute value) (pu) |
tb_pah2 | Lower limit of valve speed at closing, (absolute value) (pu) |
tb_ahlim | Upper limit of valve opening (pu). |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323