Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Misc. | OPTIME

OPERATION TIME – [OPTIME]
Returns up to 6 time values crossing the threshold in function of the direction selection.


CATEGORY
Miscellaneous

DESCRIPTION
Returns up to 6 time values crossing the threshold in function of the selected direction. Note that auto selection in Direction will select rising if the signal at t=0 is lower than the threshold and falling if the signal is higher than the threshold.


RESULT VARIABLES AND PARAMETERS

Result:

op_t1Output time 1
op_t2Output time 2
op_t3Output time 3
op_t4Output time 4
op_t5Output time 5
op_t6Output time 6


Parameters:

SignalInput signal
ThresholdThe threshold used to compare the input signal and return the output time
Direction[auto] : If input(0) >= Threshold, Direction = falling. If input(0) < Threshold, Direction = rising
[rising]Output time will be the first six rising edge that cross the threshold
[falling]Output time will be the first six falling edge that cross the threshold
[both]Output time will be the first six rising and falling edges that cross the threshold
Reference TimeThe output time is represented by the crossing time-shifted by the reference time. If the first crossing occurs at t=1.0 and Reference Time = 0.25, op_t1 will be 0.75.


SYNTAX

[op_t1,op_t2,op_t3,op_t4,op_t5,op_t6]=optime(Input,Threshold,both,Time_Shift)


CHARACTERISTICS
Data type support
Double Floating point


EXAMPLE
Where Threshold = 0.5 and Time_Shift = 0

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323