Open State ResistancesResistances of phases A, B and C of the switch in open state (ohm)
Closed State ResistancesResistances of phases A, B and C of the switch in the closed state (ohm)
Holding CurrentCurrent threshold value below which the valve is automatically blocked. Not relevant for the ideal switch (A)
Snubber CapacitanceThe capacitance of the RC snubber branch in parallel with the valve (F)
Snubber ResistanceThe resistance of the RC snubber branch in parallel with the valve (ohm)
Forward Break OvervoltageThe highest value of overvoltage across a blocked valve. Relevant only for the diode, the GTO and the thyristor (V)
Reverse Break OvervoltageThe highest value of over-voltage across a valve. Relevant only for the diode, the thyristor and the GTO (V)
Turn-off Time The lowest time interval during which the voltage across the valve must stay negative to avoid the valve being fired again when the forward voltage turns positive. Relevant only for thyristor (s)
GTO Maximum Breakable CurrentMaximal value of the GTO current that can be turned off by the GTO turn off command. Relevant only for the GTO (A)
Forward Voltage DropMinimal forward voltage for which valve firing is possible. Relevant only for the diode, the thyristor and the GTO (V)