HIL2GO-200 - I/O Group 1, Section B (CH 00-31) - Digital Inputs or Outputs (OP5369)
Connected I/O module is OP5369 32-Channel Digital IO Board
Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37 specifications of I/O module OP5369.
Connector P1 |
| Connector P2 | ||||||
---|---|---|---|---|---|---|---|---|
DB37F Pin | Assignment | DB37F Pin | Assignment | DB37F Pin | Assignment | DB37F Pin | Assignment | |
1 | +D00 | 20 | GND | 1 | +D16 | 20 | GND | |
2 | +D01 | 21 | GND | 2 | +D17 | 21 | GND | |
3 | +D02 | 22 | GND | 3 | +D18 | 22 | GND | |
4 | +D03 | 23 | GND | 4 | +D19 | 23 | GND | |
5 | +D04 | 24 | GND | 5 | +D20 | 24 | GND | |
6 | +D05 | 25 | GND | 6 | +D21 | 25 | GND | |
7 | +D06 | 26 | GND | 7 | +D22 | 26 | GND | |
8 | +D07 | 27 | GND | 8 | +D23 | 27 | GND | |
9 | +D08 | 28 | GND | 9 | +D24 | 28 | GND | |
10 | +D09 | 29 | GND | 10 | +D25 | 29 | GND | |
11 | +D10 | 30 | GND | 11 | +D26 | 30 | GND | |
12 | +D11 | 31 | GND | 12 | +D27 | 31 | GND | |
13 | +D12 | 32 | GND | 13 | +D28 | 32 | GND | |
14 | +D13 | 33 | GND | 14 | +D29 | 33 | GND | |
15 | +D14 | 34 | GND | 15 | +D30 | 34 | GND | |
16 | +D15 | 35 | GND | 16 | +D31 | 35 | GND | |
17 | +12 V* | 36 | GND | 17 | +12 V* | 36 | GND | |
18 | Vuser 1 | 37 | Vrtn 1 | 18 | Vuser 2 | 37 | Vrtn | |
19 | Not used |
|
| 19 | Not used |
|
|
* Internally provided by the simulator. Non-isolated, limited to 400 mA.
If used as digital output, channels will require a Vuser reference of 4.5 to 24 Vdc max (default internal 4.5 volts), which is provided through the DB37 connector pin 18 and referenced to Vrtn pin 37.
The OP5369 32-channel digital IO board can be configured per 8-channel subsection to be used as digital inputs or digital outputs. The following table is a list of parameters to configure as input or output.
I/O MODULE OPTION BLOCK | ||
Parameters | CH00-07 / CH08-15 / CH16-23 / CH24-31 | |
Controller Name | 'OP4610XG OpCtrl' | |
Mezzanine-type I/O module | ||
Direction | Input | Output |
Threshold low (volt) | 0.470 to 29.4 V | N/A |
Threshold high (volt) | 0.470 to 29.4 | N/A |
DIGITAL OUTPUT BLOCK PARAMETERS | ||||
Parameters | CH00-07 | CH08-15 | CH16-23 | CH24-31 |
Controller Name | 'OP4610XG OpCtrl' | |||
Data In Port Number | 15 | 16 | 17 | 18 |
Number of channels | 8 | 8 | 8 | 8 |
Digital Output Type |
|
|
|
|
DIGITAL INPUT BLOCK PARAMETERS | ||||
Parameters | CH00-07 | CH08-15 | CH16-23 | CH24-31 |
Controller Name | 'OP4610XG OpCtrl' | |||
Data Out Port Number | 15 | 16 | 17 | 18 |
Number of channels | 8 | 8 | 8 | 8 |
Digital Input Type |
|
|
|
|