OP8110-6 Console GUI

This block implements an interactive GUI for the user to control the OPAL-RT amplifier. The block allows the user to see if the system or the amplifiers have faults, allows to enable or disable the DC link and the output of each amplifier "group" and the amplifier . Each amplifier "group" consists of three amplifiers. 

Mask and Parameters

The GUI changes based on the configuration selected in the amplifier communication block (shown in OP8110-6 Interface Group Communication Block). Each amplifier "group" can have three modes of operation and the following is an illustration of the GUI in each of its mode of operation. 

Mode: 3PH INDEPENDENT

Mode: 3PH GROUPED

Mode: 1PH DIFFERENTIAL


NameDescription
STATUS GLOBAL

This section of the GUI deals with the overall OP8110 system operation. It shows "SYSTEM IS OK" if there is no system fault. It will show "FAULT" if there is one. It also displays the mode of operation of the amplifier GROUP i.e. 3PH INDEPENDENT, 3PH GROUPED or 1PH DIFFERENTIAL.

The RESET ALL button can be used to reset all the faults of the amplifier and ready it for re-initialization. 

GROUP1 DC BUS

This section shows the status of the DC link for each amplifier GROUP.

DC OUTPUT charges the amplifier group DC LINK and connects it to the amplifier DC inputs.

DISABLE disconnects the DC Link from the amplifier DC inputs. 

The status of the DC link is also displayed here. 

DC BUS ON !! - means the DC bus is turned on

OFF - means the DC link is turned off


AMPLIFIER PHASE 1: VOLTAGE CONTROL

This section show the status of the amplifier phase.

It shows if the amplifier is in GUI CONTROL MODE or in MODEL CONTROL MODE (as selected in the OP8110-6 Interface Group Communication Block)

ENABLE OUTPUT  turns on the amplifier output.

DISABLE turns off the amplifier output. 

The status of the amplifier phase is also displayed here. 

OFF - means the output is turned off

FAULTY LEG!! - means there is a fault on the amplifier

OUTPUT ON !! - means the amplifier is powered on.

The input and output of the block directly communicate with the OP8110-6 Interface Group Communication Block.