Documentation Home Page RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

RT-LAB | Release Notes 2019.3

Table of Contents

Table of Contents

2019.3.2

  • PICKERING: Added support for 50-297-041 and 40-298-050 resistive cards (DRV-3085)

  • RT-LAB: No longer changes the Python default version present on the target with RedHat 32bit LINUX. 2.4 is maintained for the system and 2.7 for scripting.

2019.3.1

  • DIANE: Added new IO interface for DIANE Ethernet-based communication protocol (DRV-3176)

  • ARINC-429: Fixed issue with the transmission when the embedded recording feature was used (DRVTT-998)         

New

  • RT-LAB: Support for Windows 64-bit

  • RT-LAB: Improved performance of connection creation

  • RT-LAB: Improved license management for ARTEMIS, based on cores

  • RT-LAB: Improved opening/closing of RT-LAB and projects

  • RT-LAB: Improved post-trigger treatment in ScopeView

  • RT-LAB: LabVIEW: Improved time to load and reset a model with panels open

  • RT-LAB: License is now based on END_OF_SUPPORT_DATE

  • RT-LAB: Optimized compilation time of Orchestra framework

  • RT-LAB: Python: Default version setup by RT-LAB is 2.7 (Host and Target)

  • RT-LAB: Python: RT-LAB API now supports Python 3.7

  • RT-LAB: Python: Versions 2.2 to 2.5 no longer supported

  • RT-LAB: Recorder: Added documentation for json configuration file for the DataViewer

  • RT-LAB: Recorder: Added internal timing

  • RT-LAB: Recorder: Users can now increase the DataLoggerTool priority

  • RT-LAB: Recorder: Users can now select SignalGroups in the DataViewer

  • RT-LAB API: Added a function to get datapoints on I/O (getConnectionPointsForIO)

  • RT-LAB API: Added a function to get the list of I/O available (getIOInterfaces)

  • RT-LAB API: Import connections function doesn't stop if the creation of a connection fails

  • RT-LAB API: Added support of linked models when using CreatePackage function

  • ePHASORSIM: New native components: GENSAL, GENSAE, ESAC1A, ESAC5A, ESAC6A, ESDC1A, ESDC2A, ESST1A, ESST4B, EXAC1, EXAC2, EXDC2, EXPIC1, IEEET1, IEEEX1, IVOEX, SCRX, URST5T, IEE2ST, IEEEST, PSS2A, PSS2B, GAST, HYGOV, IEESGO, CRANIT (exclusively for PSS/e dyr input file)

  • ePHASORSIM: A new example with CRANIT based on Kundur's two-area system is added (PHASOR-24)

  • ePHASORSIM: Optimizations in the run-time performance up to 30%

  • ePHASORSIM: Extensive warning messages are added to prevent of using invalid dynamic parameters. These messages are visible via "Diagnostic Viewer" in Simulink file

  • TCP/UDP: Added new IO interface for TCP/UDP communication (DRV-3106)

  • OPAL-RT Board: Added support for distributing connections onto multiple subsystems (DRV-3061)

  • OPAL-RT Board: Added support for OP4510 chassis using a TE0741 410T FPGA (DRV-3059)

  • CAN: Added support for ARXML DB files (DRV-3138)

  • CAN: Added option to enable/disable a channel (DRV-3171)

Bug Fixes

  • RT-LAB: Bugfix on aliases (refresh and creation)

  • RT-LAB: Bugfix on DisconnectAll in configuration view

  • RT-LAB API: Bugfix on export connections function

  • RT-LAB API: Bugfix on import connections with ~3000 connections

  • RT-LAB: Bugfix on RT-LAB uninstall from 64-bit targets

  • RT-LAB: Bugfix on VariableTable and WorkingSets (refresh and signals assignation through drag and drop)

  • RT-LAB: Bug fix related to use of OpWriteFile ("daemon is busy")

  • RT-LAB: Changed Serial Number images for licenses

  • RT-LAB: LabVIEW: Bugfix on connections not loaded in panels

  • RT-LAB: LabVIEW: Bugfix on connections only available after a close/open of the project in the configuration view

  • RT-LAB: LabVIEW: Bug fix when re-opening panels after a close/open of RT-LAB or the project

  • RT-LAB: LabVIEW: Bug fix when saving and closing panels

  • RT-LAB: Recorder: Bugfix memory leak

  • RT-LAB: Recorder: Bugfix on deleting a recorder

  • RT-LAB: Recorder: Bugfix on icons displayed in the UI (red circle/blue square)

  • RT-LAB: Recorder: Bugfix on trigger value and holdoff parameter

  • RT-LAB: ScopeView: Bugfix on frame, conversion from steps into seconds

  • RT-LAB: ScopeView: Bugfix on live acquisition with a length upper than 4 seconds

  • RT-LAB: ScopeView: Bugfix on splash screen

  • RT-LAB: ScopeView: Bugfix to have scope unit into seconds

  • ePHASORSIM: For OpenModelica based FMU's a 32bit compiler (in RT-LAB/Development/Compiler tab) must be chosen when localhost is the simulation target.

  • CAN: Fixed issue when importing a signal that has Motorola endianness (DRV-3163)

  • C37.118: Fix issue of fraction of a second not properly rounded (DRVTT-897)

  • Modbus: Ensure that the driver binds on the network interface specified in the configuration (DRVTT-894)

  • VC707 Sfunction driver: Fix voltage range issue for group 3B of the OP5607 chassis (DRVTT-914)

  • OPAL-RT Board: Improve search for bitstream binary file (DRVTT-933, DRVTT-904)

  • OPAL-RT Board: Fix support for Encoder functionality on remote systems (DRVTT-921)

  • OPAL-RT Board: Keep the configuration of the synchronization cable when switching between master and slave modes (DRVTT-887)

  • OPAL-RT Board: Fix synchronization issues with MuSE simulations running on OPAL-RTLinux (x64-based) platforms (DRVTT-905)

  • ARINC429: Fix issue of JSON configuration file modification not detected (DRVTT-925)

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323