Machine controller data come from ElmDsl sections in the DGS-XML file.
These PowerFactory components are mapped to the components of the Native Library.
The version of the ElmDsl components can be determined using the following pattern:
Version | Type Prefixes |
---|---|
PowerFactory 2022 and prior versions | Exciters: avr_ |
Governors: gov_ | |
Stabilizers: pss_ | |
Overexcitation limiters: oel_ | |
Underexcitation limiters: uel_ | |
PowerFactory 2023 and more recent versions | Exciters: exc_PSSE_ |
Governors: gov_PSSE_ | |
Stabilizers: pss_PSSE_ | |
Overexcitation limiters: oel_PSSE_ | |
Underexcitation limiters: uel_PSSE_ |
Up to v2020.4, it was possible to use FMU library with PowerFactory input files to cover a wider range of the control models. This feature has been disabled in the current release.
The remote bus feature is also not supported in stabilizers with PowerFactory input files.
Please refer to Mapping to PowerFactory parameters for more details about this disabled feature.