Block
Mask
Description
This Biss-C Master Packing block recovers the data from the I/O controller block and generates the signals needed by the DataOut block.
Parameters
This block has no parameters.
Inputs
Ready | Signal received from the Biss Master. It indicate that the Biss Master configuration is done. |
NER | Signal received from the Biss Master. It indicates "Error message" when NER is in low state. |
Status_information1 | Status Information 1 when NER = 0 (see Biss Master for further details). |
Status_information2 | Status Information 2 when NER = 0 (see Biss Master for further details). |
Instruction_register | Data received from the Biss Master. It contains the value of the instruction register. |
PositionValue | Data received from the Biss Master. It contains the position value of the Biss-C Slave. |
Outputs
DataOut | This signal contains the data of an analog subsection and a valid bit. It is meant interfacing the DataOut block. |
DataSync | This signal represents a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block corresponding to the channel selected for the DataOut signal. |
Characteristics and Limitations
This block has no specific characteristics or limitations.