Description

This Biss-C Master Packing block recovers the data from the I/O controller block and generates the signals needed by the DataOut block.

Parameters

This block has no parameters.

Inputs

ReadySignal received from the Biss Master. It indicate that the Biss Master configuration is done.
NERSignal received from the Biss Master. It indicates "Error message" when NER is in low state. 
Status_information1Status Information 1 when NER = 0 (see Biss Master for further details).
Status_information2Status Information 2 when NER = 0 (see Biss Master for further details).
Instruction_registerData received from the Biss Master. It contains the value of the instruction register.
PositionValueData received from the Biss Master. It contains the position value of the Biss-C Slave.

Outputs

DataOutThis signal contains the data of an analog subsection and a valid bit. It is meant interfacing the DataOut block.
DataSyncThis signal represents a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block corresponding to the channel selected for the DataOut signal.

Characteristics and Limitations

This block has no specific characteristics or limitations.