Documentation Home Page Specialized Solutions Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Version History

Version 1 Next »


   


Description

The OP1450 is an external bus bar mapping box, that allows paralleling of three amplifiers outputs.

It features:

  • Line-In connections: 6 X 4 Safe Banana Sockets 
  • Line-Out connections: 2 X 4 Screw Terminals with Protection Guard
  • Maximum current per each Line-In: 20A
  • Maximum current per each Line-Out: 60A
  • Maximum total Line-Out current (after connecting the jumper cables): 120A
  • Maximum rated voltage (to GND): 500V

Functional Overview

Electrical Schematic

Rear panel connections