OP1450 External Busbar

Documentation Home Page Specialized Solutions Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OP1450 External Busbar

OPAL-RT no longer sells this product. All warranties and support terms remain valid.
OP1400PR PHIL Prime Test Bench Series (user manual | web page) replaces this product. For details, contact your local sales representative or OPAL-RT support.

Page Contents

Description

The OP1450 is an external bus bar mapping box, that allows paralleling of three amplifiers outputs.

It features:

  • Line-in connections: 6 × 4 Safe Banana Sockets 

  • Line-out connections: 2 × 4 Screw Terminals with Protection Guard

  • Maximum current per each Line-In: 20A

  • Maximum current per each Line-Out: 60A

  • Maximum total Line-Out current (after connecting the jumper cables): 120A

  • Maximum rated voltage (to GND): 500V

Functional Overview

Electrical Schematic

Rear panel connections

Rear panel connections