Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image RemovedImage Added

Block



Panel
titleTable of Contents

Table of Contents
maxLevel3


Description

The frequencyDependentLine block allows to configure a frequency dependent line in the eHS solver.

It requires a firmware compiled with the XSG frequencyDependentLine block.


Mask Parameters

FD Line Desc. File: This parameters displays the selected file with the line dynamic. The file can be choosen using the button on the right.

Line Length (km) This parameters displays the line length that will be simulated. This should match the information found in the file with the line dynamic selected above.

Sample Time: This parameters allows to do offline simulation. This parameter should match the time-step set in SimPowerSystem Simscape Electrical Specialized Power Systems (SPS) Power Gui. During real-time simulation, the sample time might be changed automatically to match the parameter set in the eHS CPU block.


Inputs

This block only has SimPowerSystem Simscape Electrical Specialized Power Systems (SPS) power ports that need to be connected to the rest of the model.


Outputs

This block only has SimPowerSystem Simscape Electrical Specialized Power Systems (SPS) power ports that need to be connected to the rest of the model.


Characteristics and limitations

Models that include this block should be provided with a detailed description document. Refer to this document to obtain more information about the block specifications.

Direct FeedthroughNO
Discrete sample timeYES
XHP supportN/A
Work offlineYES


If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.